Water
Heater Info Document (Below)
Water
Heater Cost Calculator
Selecting the most efficient type
and size of hot water heater for your home can be a daunting
task. Many factors
should be taken into consideration.
1.
Energy
type and cost
2.
Type of water
heater
3.
Water
needed and frequency of use
4.
Installation, Location, Insulation
1.
Energy
Type and Cost
Water
heaters are manufactured for most forms of energy, electric,
propane, natural gas, fuel oil, wood, and heat pump.
Water heaters are required to list an energy factor (EF)
rating. Water
heaters can be stand alone, or integrated into the homes heating
and cooling systems. The
attached chart shows examples of cost comparisons between
different fuel and heater types.
The water usage figures used on the comparison
spreadsheet are 53 gallons per day, 19,345 annually (DOE
estimates for an average family of 4).
Energy cost must be converted to a per BTU cost to
compare different fuel types.
2.
Type of Water
Heater
a.
TANK/STORAGE TYPE
The most common type of water heater is a
storage or tank type heater.
These types of heaters use an insulated tank, typically
40 to 80 gallons. Water
is heated by 2 heat elements, 3000 to 5000 watts each. The
elements are thermostatically switched so only one element is on
at a time. These types of heaters are often integrated with
other heat sources using the typical tank heater as storage and
or backup unit. Tank
type units can also provide a limited amount of hot water
(depending on water system type) during power outages.
These units are manufactured in a wide variety
of shapes and sizes. Fiberglass tanks with bowl shaped bottoms
are available that are built to minimize mineral build up
associated with traditional steel flat bottom tanks. Fiberglass
is more expensive but lasts much longer than steel tank units.
Depending on mineral contents in the water fiberglass
tanks may be well worth the extra money.
b.
WHOLE HOME ON
DEMAND
On demand water heaters are manufactured in
many energy forms. Gas,
fuel oil, and electric are the most common forms.
Any time fuel (gas or oil) is burned, some of the BTU
released in combustion is exhausted through the flue, resulting
in a loss of energy, therefore EF ratings are lower.
On demand heaters do not store heated water, except for
the amount in the heating coils, typically less than 5 gallons.
On demand heater specifications show a temp rise at a
specified flow rate, therefore it is critical to know the flow
needed and in-coming water temp to properly size the units.
Manufacturer’s web sites provide calculators for this
purpose.
Electric on demand heaters are not widely used
because the average home electrical service is not sized to
accommodate the added electrical load.
It should be noted that this overload affects the Utility
Transformer and wire, as well as the distribution center and
wiring in the house. The cost of properly building or upgrading
the existing electrical system usually makes whole home electric
on demand water
heaters cost prohibitive.
c.
HYBRID OR HEAT
PUMP
Hybrids use a combination of heat pump and
storage type, and are by far the most efficient of the water
heater types. They
are also the most expensive.
Heat pumps rely on heat transfer rather than actual heat
production. Open air
pumps remove heat from the air and transfer it to the water.
The “used air” expelled from the pump is cold, so in
the summer they can actually help with home cooling.
However, during heating months the expelled air must be
reheated by the home heating system thereby reducing the overall
efficiency of the house. Hybrid
heaters also utilize a standard tank type heater for storage and
backup, so the demand charges for the backup elements apply if
they are used.
3.
Hot
Water needed and Frequency of Use
There are several websites available to aid in
figuring the amount of hot water a home needs.
When replacing existing units, don’t assume you need
the same size. Due
to advances in water saving appliances and low-flow faucets you
may be able to purchase a smaller unit.
Another consideration is the frequency of hot water
usage. If the home
is for an average family of four the Department of Energy
Average (53 gal/day) is probably accurate.
But if the hot water system is only used occasionally, or
very little hot water is used, then a demand type heater
(propane or fuel oil) becomes more cost effective.
4.
Insulation,
Location, Installation
The insulation on storage type water heater is the main
contributing factor in the EF rating.
Electric resistive heat is 100% efficient (no heat losses
due to combustion). Generally
the higher the EF rating the better insulated they are, and the
less reheating of water occurs.
A good rule of thumb is if the heater is hot or even warm
to the touch more insulation is required.
Caution should be exercised when installing insulating
blankets. Electrical
wiring can overheat and degrade if the blankets cover the wiring
access panels.
Location
within the home should also be a large factor considered. Heaters
installed in cold areas of the house (unheated basement or crawl
space) will require much more energy to heat and will reheat
more often. A
centrally located heater will contribute to heating the home.
As water cools the heat escapes the heater. During
heating seasons this will
off-sets space heating cost.
Conversely, during air conditioning season escaping heat
will create more
heat in the space you are trying to cool. The best answer is to
keep the water heater in a warm environment and keep the heat in
the water.
|